News · 28 Oct 2026 · arXiv (quant-ph)
Preprint: QLDPC surgery measures individual logical qubits inside one code block on Quantinuum's H2-2
A sourced note from the 30 October 2026 morning scan. The figure of record is the original report, not this page.
Preprint (not peer-reviewed); hardware result on a small code ([[10,2,3]]).
Surabhi Luthra and Alex Owens implemented QLDPC surgery on a [[10,2,3]] generalised bicycle code on Quantinuum's H2-2 trapped-ion processor. A single-round measurement of one logical operator using seven gadget qubits had a 0.72% error rate; decoding over three rounds of syndrome extraction brought it below 0.26%, while the untouched second logical qubit was preserved with 0.21% error. They also measured conjugate operators in sequence, reusing the gadget qubits, with a 1.12% error.
Why it matters
High-rate QLDPC codes promise much lower qubit overhead than the surface code, but only if you can operate on one logical qubit at a time; this is a hardware check of that primitive.
Source: arXiv (quant-ph) — 28 Oct 2026