News · 6 Nov 2026 · PRX Quantum

Waterloo team compensates power-line-synchronized control errors in software, recovering 99.93(1)% single-qubit gate fidelity

A sourced note from the 7 November 2026 morning scan. The figure of record is the original report, not this page.

PRX Quantum journal article: title, authors, DOI and November 6 online publication verified in APS-deposited Crossref metadata. Experimental details from the arXiv manuscript; DOI resolves to APS but the landing page blocks automated access. Single-ion control result, not logical error correction.

Tathed, Zutt, Epstein and Senko (University of Waterloo) show that disturbances that repeat in step with a trigger, here magnetic-field shifts synchronized with the lab's AC mains power, can be measured and cancelled by updating control frequency and phase in software instead of shielding. On a trapped barium-137 ion they cut the AC-line contribution to oscillator detuning by 21(9) times, pushed the residual phase below measurement uncertainty, recovered 99.93(1)% average single-qubit gate fidelity on a magnetic-field-sensitive qubit, and raised the success of the Bernstein–Vazirani algorithm on a 16-level qudit from 10(7)% to 70(9)%. arXiv: https://arxiv.org/abs/2606.00358

Why it matters

The experiment shows a software calibration method for reproducible, trigger-synchronized control errors on a single trapped ion, including a 16-level qudit. It does not remove arbitrary noise or demonstrate fault-tolerant error correction.

Source: PRX Quantum — 6 Nov 2026

Also: arXiv manuscript — experimental details · APS-deposited publication metadata (Crossref)